Pentair CP-1000 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Akcesoria do basenów naziemnych Pentair CP-1000. Pentair CP-1000 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
CP-1000 POOL OR SPA CONTROL SYSTEM
IMPORTANT SAFETY INSTRUCTIONS
Basic safety precautions should always be followed when operating and servicing
this electrical equipment, and when using the spa.
READ AND FOLLOW ALL INSTRUCTIONS.
Prolonged immersion in hot water may induce hyperthermia.
Hyperthermia occurs when the internal temperature of the body reaches a level several
degrees above the normal body temperature of
98.6"
F.
The symptoms of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an
increase in the internal temperature of the body.
The effects of hyperthermia include:
1)
unawareness of impending hazard; 2) failure to
perceive heat;
3)
failure to recognize the need to exit the spa;
4)
physical inability to exit
the spa;
5)
fetal damage in pregnant women; and 6) unconsciousness, resulting in a
danger of drowning.
WARNING: The use of alcohol, drugs or medication can greatly increase the risk
of fatal hyperthermia in hot tubs and spas.
The water in a spa or hot tub should never exceed
1040
F.
Water temperatures between
1
OOo
F.
and
1040
F.
are considered safe for a healthy
adult. Lower temperatures are recommended for extended use (exceeding
15
minutes)
and for young children.
Before entering the spa, the user should always check the water temperature with an
accurate thermometer.
Since excessive water temperatures have a high potential for fetal damage
dl~ring the
early months of pregnancy, pregnant or possibly-pregnant women should limit spa
water temperatures to
100"
F.
The use of alcohol, drugs, or medication before or during spa use may lead to
unconsciousness with the possibility of drowning.
Persons suffering from obesity or with a medical history of heart disease, low or high
blood pressure, circulatory system problems, or diabetes should consult a
physicia~i
before using the spa.
Persons using medication should also consult a
physiciar~ before using the spa, since
some medications may induce drowsiness or affect heart rate, blood pressure or
circulation.
Before using this electrical equipment, obtain a copy of the Installation Instructions and
a completed EQUIPMENT CHECKLIST from the Pool Builder, Electrician, or Start-up
Person.
SAVE THESE INS'TRUC'TIONS
Computerized
Pool
Sptems
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1

CP-1000 POOL OR SPA CONTROL SYSTEM IMPORTANT SAFETY INSTRUCTIONS Basic safety precautions should always be followed when operating and servicing this

Strona 2

CUSTOM CLOCK OPTIONS The standard CP-1000 Controller is provided with six programs plus the "Filter Pump Off" safety delay. Your Pool Builde

Strona 3 - SAFETY FEATURES

POOL CLEANER CONTROL: If your system incorporates a pool cleaner, AUX 1 Equipment Button Whenever the pool cleaner (AUX 1) is switched on, the filter

Strona 4 - CONTROLLER

Located in close proximity to your pumping equipment, the U-1000 POWER CENTER provides your Pool Serviceperson with manual control of the system witho

Strona 5 - EQUIPMENT CONTROL:

REMOTE CON'TROLS SPA-SIDE REMOTE: One or more 3-function waterproof Remote Controls (called SLIPERSWITCH) may be located at your spa. This will

Strona 6 - SETTING THE CLOCK

VALVE OPERATORS: Your control system is designed to activate an optional motorized solar valve (model VOR-24), which automatically diverts the flow of

Strona 7 - PROGRAMMING

MAINTENANCE SERVICING THE VALVES: If your system has been plumbed with the Compool Pro Valve, maintenance is a simple operation which can be Derforme

Strona 8 - 6"

TROUBLE-SHOOTING Your control system is designed to provide years of trouble-free enjoyment. However, if at any time your system appears to malfunctio

Strona 9 - DELAY CANCEL:

Compool Corporation warrants to the purchaser of this electronic control system, for the period of one year from the date of original purchase for us

Strona 10 - CUSTOM CLOCK OPTIONS

INTRODUCTION The CP-1000 is an electronic control system which is designed to coordinate and operate all of the equipment associated with your spa or

Strona 11 - EIGHT PROGRAMS:

CONTROLLER Installed in a convenient location inside your house, the CP-1000 CONTROLLER gives you fingertip control of all the equipment associated wi

Strona 12 - REMOTE CONTROLS:

EQUIPMENT CONTROL: The Controller houses a 24 hour Clock with a digital display, which is used to program daily filtration cycles and auxiliary equipm

Strona 13 - REMOTE CON'TROLS

EQUIPMENT CONTROL TIME MODE: In Time Mode (normal operation), the Clock will display the actual time of day, and "TIME" will appear on the r

Strona 14 - VALVE OPERATORS:

PROGRAMMING It is possible to preset six programs during a 24 hour period. Each of the six programs can be used for turning equipment ON or OFF. More

Strona 15 - MAINTENANCE

"PROG 3" will now appear on the right of the Display. This indicates tt Enter the third program time (6:30 pm) by pushing the HOURS and MINU

Strona 16 - TROUBLE-SHOOTING

UNUSED PROGRAMS: Our sample program utilizes all six programs. However your personal three or four of the available programs. In this event, we reco

Komentarze do niniejszej Instrukcji

Brak uwag