LX-100EZ EASYTOUCH POOL/SPA CONTROL SYSTEM
INSTALLATION AND OWNERS MANUAL
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400
Important Notice
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
Przeglądanie stron 0
1 2 3 4 5 6 ... 31 32

Podsumowanie treści

Strona 1 - SAVE THESE INSTRUCTIONS

Rev. F 3-26-04 1 P/N 520050LX-100EZ EASYTOUCH POOL/SPA CONTROL SYSTEMINSTALLATION AND OWNERS MANUALIMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL I

Strona 2 - INSTALLATION MANUAL

P/N 520050 10 Rev. F 3-26-04RECEIVER CIRCUIT BOARDMounted to the back of the LX-100 RF Power/Load Center is the Receiver Circuit Board.On the circuit

Strona 3 - OWNER’S MANUAL

Rev. F 3-26-04 11 P/N 520050Receiver TransmitterS1SwitchCOMMUNICATION LINK ADJUSTMENTNOTE: All Program Switches are Factory set to “ON”.Matching Code

Strona 4 - This page is blank

P/N 520050 12 Rev. F 3-26-04VALVE ACTUATORSRemove knob, handle and four screws from cap of valve(s) to be motorized, and use the four mounting screw

Strona 5 - INSTALLATION MANUAL

Rev. F 3-26-04 13 P/N 520050HEATER CONNECTIONSDUAL THERMOSTAT GAS HEATER/HEAT PUMPInside the heater, connect three 18 AWG wires in parallel with the

Strona 6 - SPA-SIDE

P/N 520050 14 Rev. F 3-26-04SYSTEM OPTIONSAUTOMATIC COUNTDOWN CYCLEThere is a 4-position configuration switch (designated S2) located on the Receive

Strona 7 - PLUMBING REQUIREMENTS

Rev. F 3-26-04 15 P/N 520050SPA-SIDE REMOTE CONTROLThe optional Spa-side Remote Control is a double-insulated device which is ETL-listed for installa

Strona 8 - EQUIPMENT POWER

P/N 520050 16 Rev. F 3-26-04POOL CLEANERFor systems which incorporate a booster pump pool cleaner, it is possible to add a mechanical time clock forp

Strona 9 - LX-100/LX-100EZ WIRING

Rev. F 3-26-04 17 P/N 520050WATER TEMPERATURE SENSORFor use with optional Indoor Control Panel only.Select a convenient location to mount the Tempe

Strona 10 - RECEIVER CIRCUIT BOARD

P/N 520050 18 Rev. F 3-26-04CP-100 (OPTIONAL) INDOOR CONTROLLER2 qty. separate 150 foot spools of 6-conductor 26 AWG communication cable are provide

Strona 11 - COMMUNICATION LINK ADJUSTMENT

Rev. F 3-26-04 19 P/N 520050SYSTEM START-UPApply power to the system.At the LX-100 RF Power/Load Center, verify that the POWER "ON" status

Strona 12 - CAUTION

P/N 520050 2 Rev. F 3-26-04INSTALLATION MANUALIMPORTANT SAFETY INSTRUCTIONS ...

Strona 13 - ELECTRIC HEATER

P/N 520050 20 Rev. F 3-26-04CP-100 OPTIONAL INDOOR CONTROL PANELIf the system has an Indoor Controller, verify that there is a TEMPERATURE Display an

Strona 14 - AUTOMATIC COUNTDOWN CYCLE

Rev. F 3-26-04 21 P/N 520050OWNER’S MANUALLX-100EZ EASYTOUCH POOL-SPA CONTROL SYSTEMIMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIO

Strona 15 - SPA-SIDE REMOTE CONTROL

P/N 520050 22 Rev. F 3-26-04INTRODUCTIONThe LX-100EZ is an electronic control system which is designed to coordinate and operate all of the equipment

Strona 16 - AUXILIARY VALVE

Rev. F 3-26-04 23 P/N 520050LX-100 RF POWER/LOAD CENTERLocated in close proximity to your pool equipment, the LX-100 RF Power/Load Center houses mec

Strona 17 - WATER TEMPERATURE SENSOR

P/N 520050 24 Rev. F 3-26-04SPA Service SwitchFor normal system operation, keep this Switch in the “AUTO” position.The “FILL” and “DRAIN” positions a

Strona 18 - Using the Crimping Tool

Rev. F 3-26-04 25 P/N 520050MOTORIZED VALVESYour control system is designed to activate two motorized valves, which automatically rotate between poo

Strona 19 - SYSTEM START-UP

P/N 520050 26 Rev. F 3-26-04SYSTEM OPTIONSSPA-SIDE REMOTE CONTROLA 4-button waterproof Remote Control may have been installed into the wall of your

Strona 20 - P/N 520050 20 Rev. F 3-26-04

Rev. F 3-26-04 27 P/N 520050INDOOR CONTROLLERInstalled in a convenient location inside your house, the Controller gives you fingertip control of all

Strona 21 - OWNER’S MANUAL

P/N 520050 28 Rev. F 3-26-04MAINTENANCECLEANING THE SPAFor cleaning or maintenance purposes, it is possible to use the Control System to automaticall

Strona 22 - P/N 520050 22 Rev. F 3-26-04

Rev. F 3-26-04 29 P/N 520050TROUBLE-SHOOTINGYour Control System is designed to provide years of trouble-free pool and spa enjoyment. However, if at

Strona 23 - LX-100 RF POWER/LOAD CENTER

Rev. F 3-26-04 3 P/N 520050OWNER’S MANUALIMPORTANT SAFETY INSTRUCTIONS ...

Strona 24 - P/N 520050 24 Rev. F 3-26-04

P/N 520050 30 Rev. F 3-26-04RF TROUBLE SHOOTING TABLESymptom Possible Cause SolutionPOWER LED does not light. LX-100 RF Power/Load Center Insure powe

Strona 25 - MOTORIZED VALVES

Rev. F 3-26-04 31 P/N 520050For questions, repairs, replacement parts, or information on possible Authorized Service Centerswithin your vicinity call

Strona 26

P/N 520050 32 Rev. F 3-26-04Pentair Pool Products1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-415110951 West Los Angeles Ave., Moorpark, CA 93021

Strona 27 - INDOOR CONTROLLER

P/N 520050 4 Rev. F 3-26-04This page is blank.

Strona 28 - WINTERIZING THE SYSTEM

Rev. F 3-26-04 5 P/N 520050INSTALLATION MANUALLX-100EZ EASYTOUCH POOL-SPA CONTROL SYSTEMIMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRU

Strona 29 - TROUBLE-SHOOTING

P/N 520050 6 Rev. F 3-26-04RECOMMENDED HYDRAULIC SCHEMATICRefer for “PLUMBING REQUIREMENTS” on page 7.CP-100CONTROLLER(OPTIONAL)LX-100RF POWER/LOAD

Strona 30 - RF TROUBLE SHOOTING TABLE

Rev. F 3-26-04 7 P/N 520050PLUMBING REQUIREMENTSPlumb system in accordance with “RECOMMENDED HYDRAULIC SCHEMATIC” on page 6, local codesand the foll

Strona 31 - Rev. F 3-26-04 31 P/N 520050

P/N 520050 8 Rev. F 3-26-04LX-100 RF POWER/LOAD CENTERSelect a convenient location to mount the LX-100 RF Power/Load Center. Ensure that the locat

Strona 32

Rev. F 3-26-04 9 P/N 520050LOW VOLTAGE CABLESInstall cable between the low voltage compartment of the LX-100 RF Power/Load Center and the various p